DSpace logo

Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.uide.edu.ec/handle/37000/2375
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorAcevedo, Byron-
dc.contributor.authorBeltrán Araujo, Franklin David-
dc.contributor.authorJefferson Andrés, Márquez Cevallos-
dc.coverage.spatialSede Quitoes_ES
dc.creatorBeltrán Araujo, Franklin David-
dc.creatorJefferson Andrés, Márquez Cevallos-
dc.date.accessioned2017-10-17T19:12:41Z-
dc.date.available2017-10-17T19:12:41Z-
dc.date.issued2017-10-
dc.identifier.citationBeltrán Araujo, Franklin David. (2017). Evaluación del desgaste de las estrías de corte de fresas quirúrgicas redondas de carburo de tungsteno en comparación desde su primer al quinto uso mediante estereoscopia tridimensional. Facultad de Ciencias Médicas. UIDE. Quito. 86p.es_ES
dc.identifier.otherBQU'055017-
dc.identifier.urihttp://repositorio.uide.edu.ec/handle/37000/2375-
dc.description.abstractObjetivo: Observar, medir y analizar el desgaste en las estrías de corte de las fresas quirúrgicas redondas de carburo tungsteno #8, de la marca Jet (Kerr) y SS White, en comparación desde su primer al quinto uso. Materiales y Métodos: Se utilizaron 32 fresas y se estandarizaron las variables: tiempo, presión, irrigación, y RPM, se obtuvieron imágenes mediante un estereoscopio tridimensional para poder realizar las mediciones respectivas. Resultados: El análisis comparativo de las mediciones de desgaste de las estrías de corte en las dos marcas se pudo constatar un resultado significativo en cada uso. Conclusión: A partir del primer uso en las dos marcas ya existe una reducción de sus medidas, por lo que se deberían usar una sola vez ya que en las mediciones fotográficas obtenidas en el estereoscopio el desgaste no es representativo pero sus fragmentos podrían alojarse como un cuerpo extraño en el hueso y causar infecciones....es_ES
dc.description.abstractObjective: To observe, measure and analyze the wear of the cutter edges of the tungsten carbide burs #8 of two brands Jet (Kerr) and SS White, comparing their first use to the fifth. Materials and Methods: 32 burs were used and the variables were standardized: time, pressure, irrigation, and RPM, the pictures were obtained through a three-dimensional stereoscope to be able to perform the respective measurements. Results: The comparative analysis of the wear measurements of the cutting edges in the two brands showed a significant result in each use. Conclusion: From the first use in the two brands already exists a reduction of its measurements, so it should be used only once because in the photographic 7 measurements obtained in the stereoscope the wear is not representative but the fragments can act as a foreign body in the bone causing infections...es_ES
dc.format.extent86p.es_ES
dc.language.isospaes_ES
dc.publisherQUITO/UIDE/2017es_ES
dc.rightsopenAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
dc.subjectFRESAS QUIRÚRGICASes_ES
dc.subjectCARBURO DE TUNGSTENOes_ES
dc.subjectESTEREOSCOPIA TRIDIMENSIONALes_ES
dc.subjectODONTOLOGÌAes_ES
dc.titleEvaluación del desgaste de las estrías de corte de fresas quirúrgicas redondas de carburo de tungsteno en comparación desde su primer al quinto uso mediante estereoscopia tridimensionales_ES
dc.typebachelorThesises_ES
Aparece en las colecciones: Trabajos Académicos de Titulación Especial

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
T-UIDE-1694.pdfTESIS A TEXTO COMPLETO3 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons