![DSpace logo](/image/logo-uide.png)
Please use this identifier to cite or link to this item:
https://repositorio.uide.edu.ec/handle/37000/7210
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Illescas Malla, Rogger Darlyn | - |
dc.contributor.author | Niola Valarezo, Jorge Rubén | - |
dc.contributor.author | Morales Guachamin, Carlos Luis | - |
dc.contributor.author | Rivas Jiménez, Katty Andrea | - |
dc.contributor.author | Criado, Asier (tutor) | - |
dc.contributor.author | González, Francisco (tutor) | - |
dc.contributor.author | Cabrera, Marcelo (tutor) | - |
dc.date.accessioned | 2024-07-18T20:30:18Z | - |
dc.date.available | 2024-07-18T20:30:18Z | - |
dc.date.issued | 2024 | - |
dc.identifier.citation | Illescas Malla, Rogger Darlyn; Niola Valarezo, Jorge Rubén; Morales Guachamin, Carlos Luis; Rivas Jiménez, Katty Andrea. (2024). Estudio comparativo solar de la comunidad “El Manantial”, ubicada en Quito; para una demanda fotovoltaica de 557,5 MW h/año y una demanda térmica de 561,886 MW-h/año. Valoración de la aportación solar en el Mix Energético. Maestría en Energías Renovables. UIDE. Quito. 188 p. | es |
dc.identifier.other | UIDE-Q-TMER-2024-8 | - |
dc.identifier.uri | https://repositorio.uide.edu.ec/handle/37000/7210 | - |
dc.description.abstract | La comunidad El Manantial ubicada en Quito, corresponde a 100 viviendas que consumen anualmente 557,5 MW-h en energía eléctrica y 561,886 MW-h en energía térmica para ACS y Calefacción.La empresa EPC ejecutará un proyecto de energía solar fotovoltaica para ahorrar el 60% del consumo de energía eléctrica, para lo cual se instalarán 21 plantas de 9kWp y 1 planta de 4kWp sumando un total de 193 kWp. El proyecto tiene un CAPEX de $167 676,97 y OPEX de $7 602,00. Con una inversión del 100% propia se calcula una TIR de 14,83%, VAN de $69 524,22 y ROI de 6,93 años; en un segundo escenario con préstamo bancario del 70% se tendría una TIR de 22,71%, VAN de $132 114,27 y ROI de 5,37 años. Adicionalmente, la empresa EPC ejecutará un segundo proyecto de plantas solares térmicas individuales sobre cada una de las 100 viviendas, con un CAPEX de $510 464,69 y OPEX de $8 457,0. Con una inversión 100% propia se estima una TIR de 8,01%, VAN de $537,67 y ROI de 11,8 años; en un segundo escenario con préstamo bancario del 70% se tendría una TIR de 9,30%, VAN de $88 337,04 y ROI de 15,42 años. The El Manantial community located in Quito, corresponds to 100 homes that annually consume 557.5 MW-h in electrical energy and 561,886 MW-h in thermal energy for DHW and Heating.The EPC company will execute a photovoltaic solar energy project to save 60% of electrical energy consumption, for which 21 9kWp plants and 1 4kWp plant will be installed, adding a total of 193 kWp. The project has a CAPEX of $167,676.97 and OPEX of $7,602.00. With a 100% own investment, an IRR of 14.83%, NPV of $69,524.22 and ROI of 6.93 years are calculated; In a second scenario with a 70% bank loan, there would be an IRR of 22.71%, NPV of $132,114.27 and ROI of 5.37 years.Additionally, the EPC company will execute a second project of individual solar thermal plants on each of the 100 homes, with a CAPEX of $510,464.69 and OPEX of $8,457.0. With a 100% own investment, an IRR of 8.01%, NPV of $537.67 and ROI of 11.8 years are estimated; In a second scenario with a 70% bank loan, there would be an IRR of 9.30%, NPV of $88,337.04 and ROI of 15.42 years. | es |
dc.language.iso | es | es |
dc.publisher | QUITO/UIDE/2024 | es |
dc.rights | openAccess | es |
dc.subject | ACS | es |
dc.subject | DEVEX | es |
dc.subject | CAPEX | es |
dc.subject | WACC | es |
dc.title | Estudio comparativo solar de la comunidad “El Manantial”, ubicada en Quito; para una demanda fotovoltaica de 557,5 MW h/año y una demanda térmica de 561,886 MW-h/año. Valoración de la aportación solar en el Mix Energético | es |
dc.type | Thesis | es |
Appears in Collections: | Tesis - Maestrías - Energías Renovables |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
UIDE-Q-TMER-2024-8.pdf | CONFIDENCIAL | 396.67 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.